Under the network pass through mode, users can send register packets from modules to the server. Registered packages are designed to enable the server to identify the data source device, or as a password to obtain authorization for server functionality. Registered packets can be sent when the module establishes a connection with the server, and can also be spliced into the registration package data at the front end of each packet as a packet. The data of the registration package can be ICCID code, IMEI code, or custom registration data.

 

AT commands

Command name Command function Default parameter
AT+ REGEN Query / settings enable registration package "off"
AT+ REGTP Query / settings register package content type "USER"
AT+ REGDT Query / settings custom registration information "7777772E7573722E636E"
AT+ REGSND Query / settings register packet sending mode "DATA"

 

Setting up software schematic diagram: