Read USR-G806(Industrial 4G Router) LOG by Xshell

 Overview

This manual introduces the method to read USR-G806(Industrial 4G Router) LOG by Xshell software.

 

1. Preparation

  • Software preparation: Xshell software.
  • Hardware connection: Power the G806 and connect G806’s LAN interface to PC. Note: G806’s LAN interface IP address must be 192.168.1.1. So if user has changed LAN interface IP address, please reset it to default address(192.168.1.1).

2. Procedure

Step 1: Run Xshell software, click ‘New’ to establish a new session.

 

read USR-G806 LOG by Xshell software-Run Xshell software

 

Step 2: Configure new session parameters as follow:

Configure new session parameters

 

Choose ‘SSH’ as protocol, write 192.168.1.1 as host and 2222 as port number. Then click ‘OK’ to establish session.

 

Step 3: Choose the new session that been established in above way and click ‘Connect’.

read USR-G806(Industrial 4G Router)  LOG by Xshell software-Choose the new session that been established in above way and click ‘Connect’

Step 4: Click ‘Accept Once’.

 

Read USR-G806 LOG by Xshell-SSH Security warning

 

Step 5: Enter usr as user name and click ‘OK’.

 

Read USR-G806(Industrial 4G Router)  LOG by Xshell-enter user name

Step 6: Enter www.usr.cn as password and click ‘OK’.

 

Read USR-G806 LOG by Xshell - set password

Step 7: In following software interface, enter logread and click ‘Enter’ on keyboard to read LOG.

 

Read USR-G806 LOG by Xshell-create new session

Step 8: Save LOG as txt file: right-click, choose ‘To Text Editor’ and choose ‘ALL’.

Save LOG as txt file

Then save txt file.

 

Save LOG as txt file