USR Cloud realize 730 Transparent Transmission

Overview

User can use USR Cloud transparent transmission group to realize transparent transmission. This transparent transmission is between a pair of transparent transmission group(Whole devices in group one to whole devices in group two) and we test it by two 730 in two groups. The application diagram as follow:

 

USR Cloud- transparent transmission group to realize transparent transmission

1.Configuration

 

Step 1: User can use setup software for 730 to configure. User can download setup software from http://www.usriot.com/usr-gm3-setup-software/.

 

USR Cloud2.png

After running the setup software, user should choose correct COM port with correct 730 serial port parameters, then click ‘Open Serial’ to open serial port and click ‘Enter cfg status’ to enter AT command mode to configure 730.

 

 USR-GM3 run the setup software

Step 2: Choose ‘Network Transmission’ as 730 work mode and configure network transparent transmission mode parameters.

 

Firstly, configure IP to clouddata.usr.cn, port to 15000 and choose TCP long connection.

USR Cloud- configure IP to clouddata.usr.cn

Secondly, enable USR Cloud function and write correct ID/password.

USR Cloud-enable USR Cloud function and write correct ID/password

 

After configuration, click ‘Set Save All Param’ to save parameters and reset the module to make configuration take effect.

USR Cloud-Set Save All Param’ to save parameters and reset the module to make configuration take effect

2.Data transmission

After configuring successfully and 730 connect to nodes in USR Cloud transparent transmission group successfully, user can test data transmission by setup software as follow:

 

USR Cloud-data transmmission